Supply Venturi Valves Pace™ Integrated Reheat Coil General Exhaust Venturi Valves Pace™ Integrated Silencer Room Pressure Sensor Thermostat Fume Hood Venturi Valves Fume Hood Controller
Supply Venturi Valves Features
  • Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation
  • High-speed actuation
  • Characterized and calibrated using NVLAP accredited test stations (Lab: 201067-0)
  • Operating pressure feedback
Pace™ Features
  • Pressure or volumetric offset control strategies
  • Airflow control utilizing Venturi Valves, Venturi FX Valves or Terminal Units
  • High speed room level network for communication to Pace and FHC controllers
  • BACnet MS/TP
Integrated Reheat Coil Features
  • Factory mounted transition
  • Coil access door
General Exhaust Venturi Valves Features
  • Electronic airflow feedback prevents dust/lint contamination from degrading airflow reading
  • Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation
  • High-speed actuation
  • Characterized and calibrated using NVLAP accredited test stations (Lab: 201067-0)
  • Operating pressure feedback
Pace™ Features
  • Pressure or volumetric offset control strategies
  • Airflow control utilizing Venturi Valves, Venturi FX Valves or Terminal Units
  • High speed room level network for communication to Pace and FHC controllers
  • BACnet MS/TP
Integrated Silencer Features
  • Factory mounted transition
  • Specifically designed for Venturi Valves
Room Pressure Sensor Features
  • Maintenance and calibration-free sensor technology
  • Accurate to 3% of reading
  • Designed to prevent buildup of airborne particulates
Thermostat Features
  • LCD or blank-face options
  • Optional humidity or CO2 sensing
  • Optional connection to room level network for commissioning
Fume Hood Venturi Valves Features
  • Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation
  • High-speed actuation
  • Characterized and calibrated using NVLAP accredited test stations (Lab: 201067-0)
  • Operating pressure feedback
  • Optional corrosion resistant coatings
Fume Hood Controller Features
  • Sash position, sidewall sensor or combination face velocity control
  • High speed response
  • LCD fume hood interface
  • Connection to room level network

LABORATORY

PRODUCT APPLICATION

Download content to help you design and layout your Laboratory HVAC system in your engineering construction documents.

Supply Venturi FX Pace™ Integrated Reheat Coil Exhaust Venturi FX Pace™ Multi-Variable Monitor Thermostat Room Pressure Sensor Room Pressure Monitor
Supply Venturi FX Features
  • Low minimum pressure operation
  • Closed-loop airflow control and measurement
  • Calibrated on NVLAP accredited test stations (Lab: 201067-0)
Pace™ Features
  • Pressure or volumetric offset control strategies
  • Airflow control utilizing Venturi Valves, Venturi FX Valves or Terminal Units
  • BACnet MS/TP
Integrated Reheat Coil Features
  • Factory mounted transition
  • Coil access door
Exhaust Venturi FX Features
  • Unique airflow measurement prevents dust/lint contamination from degrading airflow reading
  • Low minimum pressure operation
  • Calibrated on NVLAP accredited test stations (Lab: 201067-0)
Pace™ Features
  • Pressure or volumetric offset control strategies
  • Airflow control utilizing Venturi Valves, Venturi FX Valves or Terminal Units
  • BACnet MS/TP
Multi-Variable Monitor Features
  • 7 or 15 in. high resolution touchscreen display
  • BACnet MS/TP or IP
  • View multiple room environment points at a centralized location
Thermostat Features
  • LCD or blank-face options
  • Optional humidity or CO2 sensing
  • Optional connection to room level network for commissioning
Room Pressure Sensor Features
  • Maintenance and calibration-free sensor technology
  • Accurate to 3% of reading
  • Designed to prevent buildup of airborne particulates
Room Pressure Monitor Features
  • Elegantly designed with the industry’s highest resolution
  • Innovative 180° LED room status indicator
  • Pressure monitoring and optional reporting of room environment points for up to three spaces
  • BACnet MS/TP

OPERATING ROOM

PRODUCT APPLICATION

Download content to help you design and layout your Operating Room HVAC system in your engineering construction documents.

Supply Venturi FX Pace™ Integrated Reheat Coil Thermostat Exhaust Venturi FX Pace™ Room Pressure Sensor Room Pressure Monitor
Supply Venturi FX Features
  • Low minimum pressure operation
  • Closed-loop airflow control and measurement
  • Calibrated on NVLAP accredited test stations (Lab: 201067-0)
Pace™ Features
  • Pressure or volumetric offset control strategies
  • Airflow control utilizing Venturi Valves, Venturi FX Valves or Terminal Units
  • BACnet MS/TP
Integrated Reheat Coil Features
  • Factory mounted transition
  • Coil access door
Thermostat Features
  • LCD or blank-face options
  • Optional humidity or CO2 sensing
  • Optional connection to room level network for commissioning
Exhaust Venturi FX Features
  • Unique airflow measurement prevents dust/lint contamination from degrading airflow reading
  • Low minimum pressure operation
  • Calibrated on NVLAP accredited test stations (Lab: 201067-0)
Pace™ Features
  • Pressure or volumetric offset control strategies
  • Airflow control utilizing Venturi Valves, Venturi FX Valves or Terminal Units
  • BACnet MS/TP
Room Pressure Sensor Features
  • Maintenance and calibration-free sensor technology
  • Accurate to 3% of reading
  • Designed to prevent buildup of airborne particulates
Room Pressure Monitor Features
  • Elegantly designed with the industry’s highest resolution
  • Innovative 180° LED room status indicator
  • Pressure monitoring and optional reporting of room environment points for up to three spaces
  • BACnet MS/TP

ISOLATION ROOM

PRODUCT APPLICATION

Download content to help you design and layout your Isolation Room HVAC system in your engineering construction documents.

Supply Venturi Valves Pace™ Integrated Reheat Coil Bio-Safety Cabinet Venturi Valve General Exhaust Venturi Valves Pace™ Thermostat Room Pressure Monitor Room Pressure Sensor
Supply Venturi Valves Features
  • Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation
  • Characterized and calibrated using NVLAP accredited test stations (Lab: 201067-0)
  • Operating pressure feedback
Pace™ Features
  • Pressure or volumetric offset control strategies
  • Airflow control utilizing Venturi Valves, Venturi FX Valves or Terminal Units
  • BACnet MS/TP
Integrated Reheat Coil Features
  • Factory mounted transition
  • Coil access door
Bio-Safety Cabinet Venturi Valve Features
  • Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation
  • High-speed actuation
  • Characterized and calibrated using NVLAP accredited test stations (Lab: 201067-0)
  • Operating pressure feedback
  • Optional mechanically set constant volume construction
General Exhaust Venturi Valves Features
  • Electronic airflow feedback prevents dust/lint contamination from degrading airflow reading
  • Medium (0.6 to 3.0 in.w.c.) or low (0.3 to 3.0 in.w.c.) pressure operation
  • High-speed actuation
  • Characterized and calibrated using NVLAP accredited test stations (Lab: 201067-0)
  • Operating pressure feedback
Pace™ Features
  • Pressure or volumetric offset control strategies
  • Airflow control utilizing Venturi Valves, Venturi FX Valves or Terminal Units
  • BACnet MS/TP
Thermostat Features
  • LCD or blank-face options
  • Optional humidity or CO2 sensing
  • Optional connection to room level network for commissioning
Room Pressure Monitor Features
  • Elegantly designed with the industry’s highest resolution
  • Innovative 180° LED room status indicator
  • Pressure monitoring and optional reporting of room environment points for up to three spaces
  • BACnet MS/TP
Room Pressure Sensor Features
  • Maintenance and calibration-free sensor technology
  • Accurate to 3% of reading
  • Designed to prevent buildup of airborne particulates

PHARMACY

PRODUCT APPLICATION

Download content to help you design and layout your Compounding Pharmacy HVAC system in your engineering construction documents.